First, the instrument function
The cable tester mainly provides test methods for cable testing and has the following functions:
(1) Conduct a continuity test on the cable;
(2) Conduct insulation test on the cable;
(3) Automatically generate cable test records and store them;
(4) to communicate with the host computer, upload test records, download and maintain the wiring table;
(5) Long-distance testing of cables through the network;
(6) Perfect self-checking ability.
Second, software function
The functions of the test software mainly include: human-computer interaction, implementation of test methods, control of test procedures, acquisition of test data, and test conclusions.
Human-computer interaction: including user login, test information entry, "start test" instruction input, error prompt and abnormal condition alarm, report template input and "print report" instruction;
? Implementation of test methods: According to test information and corresponding algorithms, control the digital multimeter, safety tester, routing chassis conduct conduction test, insulation resistance test and electrical strength test, and record test data.
? Control test process: the test process needs to control the order of execution of the test items, the power-on sequence of the instrument, etc., as well as the real-time transfer of data generated during the test process;
Data analysis: After the execution of the test item, the acquired raw data is stored in the database. The test software gives the final test conclusion after calculation and comparison according to pre-given criteria and analysis methods.
Third, equipment performance indicators
(1) Insulation test
Test voltage: ≥500V
Resistance range: ≥500MΩ
Resistance measurement error: ≤ 5%
(2) Conduction test
Measuring range: 0Ω~20Ω, 200Ω, 2KΩ;
Measurement error: ≤0.5%
(3) Electrical strength test
Test voltage (Vrms): ≥500V
Frequency: 50Hz
Measuring range: (1 ~ 5000) μA
Measurement error: ≤ 4%
(4) Cable number: 300 (can be further expanded if necessary)
(5) Continuity test speed
Minimum connection time: 50ms
Minimum test time: 50ms/point
(6) Volume: less than 600mm × 800mm × 1000mm
(7) Quality: ≤150kg
(8) Transportation
Can be transported by highways and railways to meet the "General Technical Requirements for Ground Electrical Test Equipment"
(9) Traceability
Calibration cycle: 1 year.
? Meet the requirements of GJB5109-2004 General Requirements Testing and Calibration for Equipment Measurement Support
(10) MTBF ≥ 500h;
(11) MTTR ≤ 30min;
(12) Lifetime: 15 years (Working 150 hours/month)
(13) Storage Environment
Temperature: -1O°C~+60°C
Relative humidity: ≤ 95%;
(14) Working environment
Temperature: 0°C~+55°C
Relative humidity: greater than 10% and less than 95%
(15) Power Supply
AC: (220±22) V
Frequency: (50±1) Hz
Project Touch Panel,Interactive Panel Capacitive Touch,Mounted Flat Panel Touch Screen,Touch Flat Panel